VT700 Field Dynamic Balancing Measuring Instrument
Introduction:
The VT700 Field Dynamic Balancing Measuring Instrument is compact and portable. From the outside, the entire instrument looks like a briefcase, developed for general vibration testing. Many vibrations cannot be measured with simple instruments, such as when adjacent disturbance frequencies are too close, or when the rotor speed is unstable or inaccessible. Even under the harshest conditions, the most accurate measurement precision can be achieved. In the field of dynamic balancing detection for rotating machinery, simply press a button to know the total vibration value of the tested machine and the unbalance amount caused by the rotating parts, making it clear at a glance whether the product is qualified.It can perform dynamic balancing on equipment on-site, as well as vibration detection and analysis. It digitally displays the equipment's rotational speed, amplitude, and phase, ultimately obtaining the weight and phase for adding (or removing) weight to achieve balance.
Classification of VT700 Field Dynamic Balancing Measuring Instrument:
1) Field dynamic balancing of rotors
2) Frequency analysis of machine vibration
3) Measurement of mechanical vibration intensity
4) Non-contact measurement of rotor shaft vibration
5) Non-contact measurement of rotor speed
Technical Parameters:
1. Instrument Appearance
The VT dynamic balancing instrument is compact and lightweight. The keyboard and display are on the front panel, while input/output sockets and various control switches are also placed on the panel.
2. Performance Indicators
Maximum number of measurement points: Dual (2)
Speed measurement: 30~30,000 rpm
General vibration measurement: 0.01~5000μm
0.01~2000mm/s
Vibration analysis: FFT spectrum analysis
Display mode: Dot matrix graphic 64X240 dot matrix LCD with Chinese menu
Keyboard: Nine keys
Dynamic balancing:
Synchronous operating speed: 300~30,000 rpm
Synchronous amplitude range: 0.01~5000μm
Vibration severity range: 0.01~2000mm/s
Phase accuracy: 0-360°±1 °
Single/double plane balancing, removes more than 96% of unbalance in one operation